Blog | Trajan Pure-Pass GLC

The throughput challenge in clinical toxicology: why consumables matter

Written by Trajan Scientific and Medical | 15 September 2026

Clinical toxicology laboratories are under increasing pressure to process more samples, deliver faster turnaround times and maintain analytical confidence - all while managing constrained resources. As LC-MS/MS and automated sample preparation become increasingly embedded in routine toxicology workflows, laboratories are looking beyond automation systems alone to improve productivity.

The next opportunity may be less obvious, and is frequently overlooked: the consumables used within the automated workflow.

Throughput is more than automation implementation

High-throughput toxicology is often associated with fast chromatography and automated sample and liquid handling. These technologies can deliver substantial productivity gains. Automated LC-MS/MS workflows, for example, can reduce manual intervention to support higher sample throughput, while high-throughput toxicology methods have demonstrated significant reductions in turnaround times.

But an automated workflow is only as productive as its weakest link.

When laboratories aim to operate continuously - particularly overnight or run walkaway methods with minimal operator intervention - every component needs to work reliably together. A single failed transfer, alignment issue or interrupted run can create a disproportionate impact: instrument downtime, samples that may need to be re-run, and staff must intervene.

This means that uninterrupted automation is becoming just as important as automation itself.

The challenge of combining glass surface performance with automation

For some challenging analytes, particularly hydrophobic compounds, surface interactions can affect sample recovery. Hydrophobic drugs can adsorb to conventional polypropylene (PP) microplates, making surface chemistry an important consideration in sample handling.

Glass surfaces can provide an alternative, but incorporating glass into automated workflows has traditionally required workarounds.

Laboratories may use glass vials (with or without inserts), or inserts placed into a polypropylene rack to provide a glass-contact surface while retaining some compatibility with automated workflows. These approaches can address the surface-interaction problem, but they introduce another consideration: compatibility with automation.

Additional components mean additional handling and positioning requirements. Vials and inserts can create misalignment, incorrect pipetting height, gripping or positioning challenges during automated liquid handling. When those challenges interrupt a run, the cost is not simply the time spent correcting the problem. It can include instrument downtime, operator intervention, re-runs, sample backlog and delayed results.

From automation to uninterrupted automation

This is where consumable selection as part of workflow design becomes strategically important.

A plate that combines a glass-like surface with a standard automated plate format can remove the need for glass vials or inserts while retaining the surface characteristics needed for challenging analytes.

Trajan's Pure-Pass GLC Well Plates use a glass-like coating technology within a standard plate format. The approach is designed to provide glass-comparable performance while avoiding the handling and alignment challenges associated with glass vials and inserts.

The significance is not simply that one consumable replaces another. It is that the consumable becomes part of the automation strategy and supports automation.

Designed for automation, Pure-Pass GLC Well Plates can help reduce the points at which an automated workflow can be interrupted. That creates an opportunity to keep instruments running for longer with less operator intervention - particularly during unattended periods.

The productivity impact goes beyond throughput

For laboratory managers, the value of uninterrupted automation extends beyond processing more samples.

Higher productivity: Fewer interruptions can help reduce downtime and manual troubleshooting, giving laboratory staff more time to focus on higher-value tasks such as reviewing, interpreting and reporting results.

Lower cost per sample: Avoiding failed transfers, re-runs and unnecessary operator intervention can reduce the effective cost of processing each sample.

Faster turnaround times: When workflows are less prone to interruption, samples can move through preparation and analysis more consistently, supporting faster delivery of results.

Greater confidence in unattended operation: If consumables are designed for automated handling, laboratories can have greater confidence in overnight or minimal-intervention workflows.

Together, these benefits show why throughput is not only a matter of automation and faster processing. The more meaningful measure is whether the workflow can keep moving reliably, with fewer avoidable interruptions.

The consumable is part of the workflow

As clinical toxicology laboratories continue to increase sample volumes, the focus on productivity will increasingly shift from individual instruments and methods to the entire sample journey.

Automation, sample preparation, analytical speed and consumable compatibility all contribute to the final result. A highly automated system can still lose productivity if a small component creates a bottleneck or requires manual intervention.

The next generation of high-throughput laboratories therefore need to ask a broader question:

Is every component of the workflow designed to support uninterrupted automation?

For challenging samples, the answer may begin with something as fundamental as the plate used to hold them.

Reliable automation requires consumables, method and instrument. The fastest workflow is the one that completes a sample the fastest, and the one that keeps running.

 

Try glass-like coating technology